Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 956
Filtrar
1.
Contact Dermatitis ; 90(2): 116-125, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37735996

RESUMO

BACKGROUND: Rubber accelerators are used in the production of rubber gloves and may cause contact allergy. OBJECTIVES: To estimate long-term trend and prevalence of contact allergy to rubber accelerators for a 30-year period in Denmark, high-risk occupations, and exposures. METHODS: Data from all patients with contact dermatitis consecutively patch tested at the department of Skin and Allergy Gentofte hospital with the rubber accelerators from the European baseline series (EBS) from 1990 to 2019, were analysed. Further, patients under suspicion of rubber accelerator contact allergy were additionally patch-tested with rubber accelerators from the specialised rubber series from 2005 to 2019 and these were additional extracted. RESULTS: The overall prevalence of contact allergy to one or more of the rubber accelerators from the EBS series was 2.7% with a significant decline in the first 12-years, followed by a stable frequency in the past 18-years. Associations with occupational contact dermatitis, hand dermatitis, and leg/foot dermatitis were found. Wet-work occupations were most often affected and gloves the most frequent exposure. CONCLUSIONS: Contact allergy to one or more of the rubber accelerators from the EBS is frequent and has been unchanged for several decades, which calls for prevention.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Eczema , Hipersensibilidade ao Látex , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Borracha/efeitos adversos , Testes do Emplastro/efeitos adversos , Dermatite Ocupacional/etiologia , Dermatite Ocupacional/complicações , Hipersensibilidade ao Látex/epidemiologia , Eczema/epidemiologia , Eczema/complicações , Dinamarca/epidemiologia
2.
Contact Dermatitis ; 90(3): 266-272, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38093646

RESUMO

BACKGROUND: Artificial nail materials are mixtures that are prone to contain several sensitizing (meth)acrylates. It is not known whether the listing of (meth)acrylates is correct in these products' packages. Protective gloves suited for nail work are needed. OBJECTIVES: To analyse (meth)acrylates in gel nail and acrylic nail products chemically and to compare the results with the information in the product labels, and to study penetration of artificial nail materials through selected disposable gloves. METHODS: We analysed 31 gel nail products and 6 acrylic nail products for their (meth)acrylate content by gas chromatography-mass spectrometry (GC-MS). We tested the penetration of two nail products through three disposable gloves: nitrile rubber, neoprene rubber and polyvinyl chloride (PVC). RESULTS: Altogether 32/37 products contained (meth)acrylates. In all of them, there was discrepancy between the listed (meth)acrylates and those discovered in the analysis. The commonest (meth)acrylates were hydroxyethyl methacrylate (HEMA, 20/37 samples) and hydroxypropyl methacrylate (HPMA, 9/37 samples), but many of the product packages failed to declare them. Isobornyl acrylate (IBA) was discovered in nine gel nail products. The neoprene glove could withstand nail gel for 20 min and thin nitrile glove and PVC glove for 5 min. Acrylic nail liquid penetrated through disposable gloves quickly. CONCLUSIONS: Labelling of artificial nail products was notably incorrect on most products. Requirements for product labelling must be updated so that the risk of sensitization associated with artificial nail products is clearly indicated. Disposable gloves can probably be used short-term in gel nail work, whereas disposable gloves do not protect the user from acrylic nail liquids.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/etiologia , Dermatite Alérgica de Contato/prevenção & controle , Unhas , Neopreno/efeitos adversos , Borracha/efeitos adversos , Testes do Emplastro/métodos , Acrilatos/efeitos adversos , Metacrilatos , Nitrilas
4.
Contact Dermatitis ; 89(3): 143-152, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37331721

RESUMO

BACKGROUND: Allergic contact dermatitis to gloves is mostly induced by rubber accelerators. The European baseline series (EBS) appears insufficient to detect glove allergy. Since 2017, it is recommended to use the European rubber series (ERS) and to test the patients' own gloves. OBJECTIVES: To investigate the clinical profile of glove-wearing patients with hand eczema (HE) and to evaluate their sensitisation profile to glove allergens and the value of testing the patients' own gloves. METHODS: We conducted a French multicentre study of patients evaluated for HE between 2018 and 2020 and tested with the EBS, the ERS and their own gloves in patch tests and semi-open (SO) tests. RESULTS: A total of 279 patients were included; 32.6% of patients had positive tests to their own gloves or to glove allergens. Almost 45% of the sensitisations to glove allergens were detected only by the ERS. Among the patients tested both in patch tests and SO tests with their own gloves with positive results, 28% had positive SO tests only. Polyvinylchloride (PVC) gloves were positive in four patients. CONCLUSION: Our series confirms the need to test the ERS. All the patients' gloves must also be tested including PVC gloves. SO tests with gloves are useful as a complement to patch tests.


Assuntos
Dermatite Alérgica de Contato , Eczema , Dermatoses da Mão , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Borracha/efeitos adversos , Eczema/etiologia , Alérgenos/efeitos adversos , Testes do Emplastro , Cloreto de Polivinila/efeitos adversos , Dermatoses da Mão/induzido quimicamente , Luvas Protetoras/efeitos adversos
6.
Int Arch Occup Environ Health ; 96(6): 797-814, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37083761

RESUMO

OBJECTIVE: This study aimed at investigate the association between cancer and the rubber tire industry using indicators used to estimate exposure, such as duration or historical time period of exposure. METHODS: A systematic review using MEDLINE was carried out. The Preferred Reporting Items for Systematic Reviews (PRISMA) statement guided the systematic review. The Risk of Bias in Non-Randomized Studies of Exposures (ROBINS-E) was used to analyze biases in the selected studies. RESULTS: A total of 240 articles were initially selected. Of these, 17 were included in this systematic review of 15 different cohorts and one case-control study. Five cohorts were composed of rubber industry employees including some who worked in the rubber tire industry, whereas the other 10 cohorts were composed exclusively of rubber tire industry employees. An increased risk of lung/respiratory cancer is possible in the oldest time periods without duration of exposure showing any association according to the analysis. The work areas of mixing and milling as well as compounding seem to be more specifically associated with this risk, which could be expected because of the exposure to fumes containing carcinogenic agents. CONCLUSIONS: Having worked in the rubber tire industry in the past, especially in milling, mixing as well as compounding may be associated with an increased risk of lung/respiratory cancer.


Assuntos
Neoplasias Pulmonares , Doenças Profissionais , Exposição Ocupacional , Neoplasias do Sistema Respiratório , Humanos , Borracha/efeitos adversos , Estudos de Casos e Controles , Indústrias , Exposição Ocupacional/efeitos adversos , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/etiologia , Doenças Profissionais/etiologia , Doenças Profissionais/induzido quimicamente
8.
Contact Dermatitis ; 88(6): 472-479, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36975130

RESUMO

BACKGROUND: The two dialkylthiocarbamyl benzothiazole sulphides, dimethyl-thiocarbamylbenzothiazole sulphide (DMTBS) and diethylthio-carbamylbenzothiazole sulphide (DETBS) were shown to be good markers of both thiuram and mercaptobenzothiazole sensitivity. OBJECTIVES: To investigate if DMTBS and/or DETBS could be better markers of contact allergy to common rubber additives than the ones currently used. METHODS: Sixty-eight dermatitis patients were patch tested with DMTBS and DETBS, both at 1% in petrolatum (pet). Because of late reactions in 10 patients, these were retested to DMTBS and DETBS in serial dilutions. Tetramethylthiuram monosulphide (TMTM) 1.0% pet was also tested. RESULTS: At the initial reading Days 3 and 7, no reactions were noted to DMTBS or DETBS. At retesting, 10 of the 68 (15%) patients reacted positively to lower concentrations of DMTBS than the initial test concentration. Seven of 8 also reacted to TMTM. Three of them had positive reactions to DEBTS. All 10 patients had reactions to more diluted solutions to DMBTS than to DEBTS (p = 0.0077; Mc-Nemar test, two-sided). CONCLUSIONS: Results speak for patch test sensitization to DMTBS with cross-reactivity to TMTM and also DEBTS. DMTBS and DEBTS could be new markers of rubber allergy but a safe test concentration must be found.


Assuntos
Dermatite Alérgica de Contato , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Borracha/efeitos adversos , Alérgenos/efeitos adversos , Testes do Emplastro/efeitos adversos , Sulfetos/efeitos adversos
9.
Asian Pac J Cancer Prev ; 24(2): 357-361, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36853282

RESUMO

INTRODUCTION: The most significant industrial utilization of carbon disulfide (CS2) has been in the manufacture of cellulose rayon, cellophane, and rubber industry. CS2 prompts expanded recurrence of chromosomal variations in laborers occupationally exposed to CS2. MATERIALS AND METHODS: In the current study, the DNA analysis was carried out from exfoliated buccal epithelial cells from rubber industry workers exposed to CS2 and an equal number of healthy control subjects. Both the control and experimental subjects were categorized by their smoking habits such as smokers (S) and non-smokers (NS). Furthermore, experimental subjects were further separated based on their exposure period. Students t-test statistical tools were used to analyze the final results. RESULTS: The present analysis identified a high frequency of DNA damage in rubber industry workers (16.55±0.43) than control subjects (9.8±0.21). Also, maximum number of DNA damage detected in smoking experimental group (18.27±0.02) than non-smoking experimental (15.02±0.01) and smoking control groups (10.25±0.04 ). CONCLUSION: Smoking habits synergistically increased the DNA damage in the rubber industry workers exposed to CS2.


Assuntos
Dissulfeto de Carbono , Humanos , Dissulfeto de Carbono/efeitos adversos , Borracha/efeitos adversos , Dano ao DNA , Comércio , Células Epiteliais
10.
Biochem Biophys Res Commun ; 629: 1-5, 2022 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-36087537

RESUMO

Fluoroquinolones are one of the most frequently prescribed antibiotics. However, their use increases the risk of Aortic aneurysm and dissection (AAD). The mechanism underlying this effect remains unclear. AAD are caused by weakening of the aortic wall and loss of vascular smooth muscle cells. Osteopontin is involved in the occurrence and development of AAD. The aim of the present study was to examine the role of moxifloxacin, a fluoroquinolone, in the occurrence of AAD using a moderate-severity AAD mouse model. Four-week-old male C57BL/6J mice were fed a high-fat diet. At 8 weeks of age, the mice were infused with saline or angiotensin II (1000 ng kg-1 min-1) via osmotic minipumps for 4 weeks, and then orally administered water (vehicle) or moxifloxacin (30 and 100 mg kg-1 day-1) for another 3 weeks. Moxifloxacin (30 and 100 mg kg-1 day-1) induced AAD and elastin degradation in aortic tissues, as revealed by hematoxylin and eosin staining and elastica-van Gieson staining. Additionally, immunohistochemical staining and Western blot analyses showed that moxifloxacin 100 mg kg-1 day-1 decreased the protein expression of smooth muscle protein 22α, one of the markers of the contractile phenotype of vascular smooth muscle cells, in aortic tissues compared to vehicle and moxifloxacin 30 mg kg-1 day-1. Furthermore, moxifloxacin (100 mg kg-1 day-1) increased the protein expression of osteopontin and matrix metalloproteinases-2 in the aortic tissues when compared to control. Moxifloxacin may induce the onset of AAD and weakening of the aortic media by increasing the expression of osteopontin and matrix metalloproteinase-2 and decreasing that of smooth muscle protein 22α in aortic tissue.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Dissecção Aórtica/induzido quimicamente , Dissecção Aórtica/genética , Angiotensina II/farmacologia , Animais , Antibacterianos/farmacologia , Aneurisma Aórtico/induzido quimicamente , Modelos Animais de Doenças , Elastina/metabolismo , Amarelo de Eosina-(YS)/efeitos adversos , Amarelo de Eosina-(YS)/metabolismo , Hematoxilina/metabolismo , Hematoxilina/farmacologia , Masculino , Metaloproteinase 2 da Matriz/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Moxifloxacina/efeitos adversos , Moxifloxacina/metabolismo , Proteínas Musculares/metabolismo , Miócitos de Músculo Liso/metabolismo , Osteopontina/metabolismo , Borracha/efeitos adversos , Borracha/metabolismo , Água/metabolismo
11.
J UOEH ; 44(3): 307-311, 2022.
Artigo em Japonês | MEDLINE | ID: mdl-36089350

RESUMO

A 42-year-old man working at a steel mill recognized itching and erythema on the dorsal surfaces of his hands for 2 weeks prior to his first visit to our department. Lichenized erythematous plaques were observed on the dorsal surfaces of his fingers and hands. A patch testing of the rubber part of the gloves showed a positive reaction. We also conducted a patch testing of metals to exclude a possibility of contact dermatitis mediated by metals as occupational materials. The patch testing of metals showed a positive reaction to zinc, which is not an occupational material in his steel mill, but his rubber gloves contained zinc in the rubber accelerators, which might have been the trigger that caused his allergic contact dermatitis. Contact dermatitis is the most common occupational skin disease, and various materials are the causative agents. Allergic reactions to rubber (latex) are classified into type I allergy and type IV allergy. Type IV allergic reaction is observed in rubber accelerators such as thiuram; however, our case showed that zinc allergy could be a possible causative agent in patients with contact dermatitis due to rubber gloves.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Adulto , Dermatite Alérgica de Contato/etiologia , Dermatite Ocupacional/complicações , Humanos , Masculino , Borracha/efeitos adversos , Aço , Zinco
12.
Curr Opin Allergy Clin Immunol ; 22(4): 250-256, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35852898

RESUMO

PURPOSE OF REVIEW: The present review addresses the secondary prevention in healthcare worker, healthcare setting, and in patients outside the healthcare setting. RECENT FINDINGS: There is sufficient knowledge of the broad aetiology of latex allergy for secondary preventive programmes to be widely adopted. Currently, avoidance of latex-containing surgical products is mandatory in the care of sensitized patients. They should also have a list of occult sources of natural rubber latex exposure and cross-reacting fruits. During all health-care procedures latex allergic patients should be treated in a 'latex-free' environment. Specific sublingual immunotherapy has been suggested as a suitable therapeutic option. It can be offered, in addition to symptomatic treatment, to selected patients, when avoidance measures are not feasible or effective. The use of omalizumab could also be extended as an adjunct to latex immunotherapy. SUMMARY: Despite of the progress made in the secondary prevention of latex allergy, the disease still continues to be a global health problem.


Assuntos
Hipersensibilidade ao Látex , Frutas , Humanos , Imunoterapia/métodos , Hipersensibilidade ao Látex/prevenção & controle , Borracha/efeitos adversos , Prevenção Secundária
14.
Dermatitis ; 33(1): 62-69, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35029350

RESUMO

BACKGROUND: Shoe contact allergy can be difficult to diagnose and manage. OBJECTIVE: The aim of the study was to characterize demographics, clinical characteristics, patch test results, and occupational data for the North American Contact Dermatitis Group patients with shoe contact allergy. METHODS: This is a retrospective study of 33,661 patients, patch tested from 2005 to 2018, with a shoe source, foot as 1 of 3 sites of dermatitis, and final primary diagnosis of allergic contact dermatitis. RESULTS: Three hundred fifty-two patients met the inclusion criteria. They were more likely to be male (odds ratio = 3.36, confidence interval = 2.71-4.17) and less likely to be older than 40 years (odds ratio = 0.49, confidence interval = 0.40-0.61) compared with others with positive patch test reactions. The most common relevant North American Contact Dermatitis Group screening allergens were potassium dichromate (29.8%), p-tert-butylphenol formaldehyde resin (20.1%), thiuram mix (13.3%), mixed dialkyl thioureas (12.6%), and carba mix (12%). A total of 29.8% (105/352) had positive patch test reactions to supplemental allergens, and 12.2% (43/352) only had reactions to supplemental allergens. CONCLUSIONS: Shoe contact allergy was more common in younger and male patients. Potassium dichromate and p-tert-butylphenol formaldehyde resin were the top shoe allergens. Testing supplemental allergens, personal care products, and shoe components should be part of a comprehensive evaluation of suspected shoe contact allergy.


Assuntos
Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatoses do Pé/diagnóstico , Sapatos/efeitos adversos , Adulto , Corantes/efeitos adversos , Estudos Transversais , Dermatite Alérgica de Contato/etiologia , Feminino , Dermatoses do Pé/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Testes do Emplastro/métodos , Resinas Sintéticas/efeitos adversos , Estudos Retrospectivos , Borracha/efeitos adversos , Adulto Jovem
19.
Dermatitis ; 32(3): 160-163, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33405485

RESUMO

BACKGROUND: Mercaptobenzothiazole compounds are associated with allergic contact dermatitis caused by rubber products. Several screening substances have been used for patch testing. OBJECTIVE: To compare the frequency of positive test reactions to a mercapto mix containing a higher concentration of 2-mercaptobenzothiazole with reactions to the combination of 2-mercaptobenzothiazole 2.0% and mercapto mix 2.0%. METHODS: There were 7103 dermatitis patients in 12 International Contact Dermatitis Research Group dermatology departments who were patch tested with 2-mercaptobenzothiazole 2.0% petrolatum (pet.), mercapto mix 2.0% pet., and mercapto mix 3.5% pet. RESULTS: Contact allergy to the 3 test preparations varied among the 12 centers: 2-mercaptobenzothiazole 2.0% pet. (0-2.4%), mercapto mix 2.0% pet. (0-4.9%), and mercapto mix 3.5% pet. (0-1.4%). 2-Mercaptobenzothiazole 2.0% and mercapto mix 2.0% detected a few more positive patients compared with mercapto mix 3.5%, but the difference was statistically insignificant (mercapto mix 2.0% pet., P = 1.0; 2-mercapto-benzothiazole 2.0% pet., P = 0.66). CONCLUSIONS: Mercapto mix 3.5% pet. is not better than 2-mercaptobenzothiazole 2.0% and mercapto mix 2.0% by a difference that is significant. By using only 1 test preparation (mercapto mix 3.5%), an additional hapten could be tested. No cases of suspected/proven patch test sensitization were registered.


Assuntos
Alérgenos/efeitos adversos , Benzotiazóis/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Testes do Emplastro/estatística & dados numéricos , Testes do Emplastro/normas , Borracha/efeitos adversos , Testes Cutâneos/métodos , Alérgenos/química , Benzotiazóis/química , Dermatite Alérgica de Contato/etiologia , Humanos , Hipersensibilidade ao Látex/induzido quimicamente , Hipersensibilidade ao Látex/diagnóstico , Testes do Emplastro/métodos , Vaselina , Sensibilidade e Especificidade
20.
PLoS One ; 15(10): e0240613, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33075091

RESUMO

BACKGROUND: Identifying the functional materials inside vaping devices can help inform efforts to understand risk. While nicotine E-cigarette components and metals have been characterized in several previous studies, the internal component compositions of tetrahydrocannabinol (THC) cartridge designs are not as well known. The 2019-20 e-cigarette or vaping product use associated lung injury (EVALI) outbreak has been associated with THC devices containing vitamin E acetate (VEA), possibly mediated by chemical reactions with internal cartridge components and high filament temperatures. METHODS: We investigate the composition and internal components of 2019 EVALI patient-associated THC vaping devices compared to other THC and nicotine devices from 2016-19, specifically the metal, ceramic, and polymer components likely to be exposed to heat. To do this, we have disassembled forty-eight components from eight used and unused vaping devices under a microscope and analyzed them using X-ray fluorescence, scanning electron microscopy, and Fourier-transform infrared micro-spectroscopy. CONCLUSIONS: The two THC cartridges used by EVALI patients exhibited evidence of localized high temperatures, including charring of the ceramic heating elements and damaged wire surfaces. The newer THC cartridges possessed more ceramic and polymer insulation than older THC or nicotine devices. The combination of ceramics, metals, and high temperatures in newer THC cartridges is consistent with conditions hypothesized to produce VEA reactions during vaping. Nickel and chromium components were detected in all devices, and others contained copper, lead, tin, gold, silicon-rich rubbers, or fluorinated microplastics. These components have the potential to thermally degrade and volatilize if heated sufficiently. These findings do not imply that harmful exposures would occur under all usage conditions, and are most relevant to harm reduction efforts based on avoiding higher internal temperatures. This study was limited to a small sample of cartridges obtained from investigations. Future work should test more device types and internal temperatures under controlled usage conditions.


Assuntos
Dronabinol/efeitos adversos , Sistemas Eletrônicos de Liberação de Nicotina , Lesão Pulmonar/patologia , Nicotina/química , Canabinoides/toxicidade , Cerâmica/efeitos adversos , Cerâmica/química , Surtos de Doenças , Dronabinol/química , Temperatura Alta/efeitos adversos , Humanos , Lesão Pulmonar/induzido quimicamente , Lesão Pulmonar/epidemiologia , Microscopia Eletrônica de Varredura , Nicotina/efeitos adversos , Plásticos/efeitos adversos , Polímeros/efeitos adversos , Polímeros/química , Borracha/efeitos adversos , Borracha/química , Vaping/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...